AC Miniature LVDT - MD

  • Info
  • Specification
  • Accessories

AC Miniature LVDT - MD

The small case diameter (6mm and 8mm) allows for easy installation in confined spaces. A right angle output facility is available as a retrofit for the 8mm version. The low core weight makes this range ideal for use in low inertia systems. Cross talk is prevented by the screened cable, which also allows for multiple use of these transducers in close proximity.

    Features:
  • 2, 5, 10, 20mm measurement range
  • Half bridge and LVDT version
  • Small 6 or 8 mm body diameter

 

MD-Series Absolute Displacement Sensor - Specification

MD Micro Series
 
LVDT
M6D/1
MD/1
MD/2.5
MD/5
MD/10
Half Bridge
M6DH/1
MD/1/H
MDH/2.5
MDH/5
MDH/10
Body Diameter
6h6
8h6
Measuremnt Range (mm)
± 1.0
± 2.5
± 5.0
± 10.0
Linearity (% reading)
0.5
Cable Length
2 m Standard
Mechanical
 
Case Material
400 Series Stainless Steel
Cable Material
PUR
Carrier Configuration
Free Core
Transducer Weight ± 0.5 (g)
2.6
5.0
7.6
8.5
13.0
Mass of Moving Components
0.1
0.2
0.3
0.7
Environmental
Storage Temperature (°C)
-40 to +105
Operating Temperature (°C)
-10 to +80
IP Rating
None
LVDT Electrical Interface1
Energising Voltage (Vrms)
1 to 10
Sensitivity at 10 kHz (± 5% mV/V/mm)
269
210
150
105
33
Energising Current at 5 kHz (ma/V)
3.0
1.8
2.0
1.0
0.6
Zero Phase Frequency (kHz)
13
10
13
10
14
Half Bridge Electrical Interface2
Energising Voltage(Vrms)
1-10
Sensitivity at 10 kHz (± 5% mV/V/mm)
83
82
51
33
Energising Current at 5 kHz (ma/V)
1.2
1.0
1.2

2All analogue Half Bridge sensors are calibrated at 3V, 10 kHz into a 1 kΩ load.

1All analogue LVDT sensors are calibrated at 3V, 5 kHz into a 100 kΩ load.

Probe Tip with Adapter for S-Series

Probe Tip Adapter with Probe Tip to fit M6 x 1.0 carrier thread

Springs for S-Series

Extension Springs are available for all guided S-Series sensors

 

Top